America's Engineering Resins Supplier
Friday, October 24, 2014
XYRON™ 540V
Units 
Asahi Kasei Chemicals Corporation - Polyphenylene Ether + PS
ActionLegend (Open)
E-mail a Datasheet Print this Page  

General Information
Product Description
Modified PPE
Unreinforced Flame retardant V-1
General  
Material Status 
  • Commercial: Active
Availability 
  • Africa & Middle East
  • Asia Pacific
  • Europe
  • North America
 
Additive 
  • Flame Retardant
Features 
  • Flame Retardant
Processing Method 
  • Injection Molding
ASTM & ISO Properties 1
Physical
Nominal Value
Unit
Test Method
1.08
g/cm³
ISO 1183
Molding Shrinkage 2 (0.0787 in)
0.50 to 0.70
%
Internal Method
Water Absorption (73°F, 24 hr)
0.10
%
ISO 62
f2
 
UL 746C
Mechanical
Nominal Value
Unit
Test Method
Tensile Stress (Yield, 73°F)
8700
psi
ISO 527-2
13
%
ISO 527-2
352000
psi
ISO 178
14200
psi
ISO 178
Impact
Nominal Value
Unit
Test Method
7.1
ft·lb/in²
ISO 179
Thermal
Nominal Value
Unit
Test Method
Deflection Temperature Under Load (264 psi, Unannealed)
248
°F
ASTM D648
Heat Deflection Temperature (264 psi, Unannealed)
237
°F
ISO 75-2/A
CLTE - Flow (-22 to 149°F)
3.9E-5
in/in/°F
ISO 11359-2
Electrical
Nominal Value
Unit
Test Method
1.0E+16
ohm
IEC 60093
1.0E+16
ohm·cm
IEC 60093
Electric Strength 4 (0.0787 in)
740
V/mil
IEC 60243-1
    IEC 60250
100 Hz
2.90
 
 
1 MHz
2.90
 
 
    IEC 60250
100 Hz
3.0E-3
 
 
1 MHz
4.0E-3
 
 
Flammability
Nominal Value
Unit
Test Method
Flame Rating (0.0287 in)
V-1
 
UL 94
Processing Information
Injection
Nominal Value
Unit
 
Drying Temperature
194 to 212
°F
 
Drying Time
2.0 to 4.0
hr
 
Processing (Melt) Temp
464 to 572
°F
 
Mold Temperature
122 to 176
°F
 
Notes
1Typical properties: these are not to be construed as specifications.
2150x150x2 mm
34 mm
4Short Time
 
UL IDES

UL and the UL logo are trademarks of UL LLC © . All Rights Reserved.

Nominal ValueThe information presented on this datasheet was acquired by UL Prospector from the producer of the material. UL Prospector makes substantial efforts to assure the accuracy of this data. However, UL Prospector assumes no responsibility for the data values and strongly encourages that upon final material selection, data points are validated with the material supplier.

www2.ulprospector.com